SDS

Safety Data Sheet
Material Name: COAL TAR CREOSOTE (PRESSURE APPLICATIONS)
SDS ID: 00227842
____________________________________________________________
Page 6 of 18
Issue date: 2015-12-30 Revision 2.6
Print date: 2016-01-06
Acute
respiratory tract irritation, mild skin irritation, eye irritation, thermal burns from heated material
Delayed
skin cancer
Section 5 - FIRE FIGHTING MEASURES
Extinguishing Media
Suitable Extinguishing Media
regular dry chemical, carbon dioxide, water spray, regular foam
Unsuitable Extinguishing Media
high-pressure water streams.
Special Hazards Arising from the Chemical
Contact with heat may generate toxic and/or flammable gases. Containers may rupture or explode if
exposed to heat.
Hazardous Combustion Products
carbon monoxide, carbon dioxide, oxides of nitrogen, polynuclear aromatic hydrocarbons
Fire Fighting Measures
Move container from fire area if it can be done without risk. Cool containers with water spray until well
after the fire is out. Do not scatter spilled material with high-pressure water streams. Withdraw
immediately in case of rising sound from venting safety device or any discoloration of tanks due to
fire. Avoid inhalation of material or combustion by-products. Stay upwind and keep out of low areas. Use
extinguishing agents appropriate for surrounding fire. Water may be used to blanket fire. Flood with fine
water spray. Directly spraying water or foam onto hot burning product may cause frothing. For fires in
cargo or storage area: Cool containers with water from unmanned hose holder or monitor nozzles until
well after fire is out. If this is impossible then take the following precautions: Keep unnecessary people
away, isolate hazard area and deny entry. Dike for later disposal.
Special Protective Equipment and Precautions for Firefighters
Wear full protective firefighting gear including self-contained breathing apparatus (SCBA) for protection
against possible exposure.
Section 6 - ACCIDENTAL RELEASE MEASURES
Personal Precautions, Protective Equipment and Emergency Procedures
Avoid inhalation or contact. Provide adequate ventilation. Wear personal protective clothing and
equipment, see Section 8. Avoid release to the environment. Collect spillage.
Methods and Materials for Containment and Cleaning Up
Keep out of water supplies and sewers. This product is toxic to aquatic organisms. Do not discharge
effluent containing this product into lakes, streams, ponds, estuaries, oceans, or other waters unless in
accordance with the requirements of a National Pollution Discharge Elimination System (NPDES) permit
and the permitting authority has been notified in writing prior to discharge. Do not discharge effluent