Specification

SPEC-DATA
ª
and MANU-SPEC
ª
are registered trademarks of Reed Elsevier Inc. The ten part SPEC-DATA format conforms to the editorial style
of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. ©2007 Reed Construction Dataª. All Rights Reserved.
damp, frosty or contaminated surfaces
Do not apply primer or membrane to
frozen concrete
Jiffy Seal is not recommended as a pond or
tank liner except for “between slab” appli-
cations
Do not apply over sealants containing tar. If
bitumen modified materials are encountered,
consult a Protecto Wrap representative for
guidance
Jiffy Seal is not designed for use as a fin-
ished traffic system
For green concrete, use Jiffy Seal No. 80
Green Concrete Primer
On rough surface areas, Jiffy Seal must be
placed over a well-adhered parget coat
4. Technical Data
APPLICABLE STANDARDS
ASTM International
ASTM D146 Standard Test Methods for
Sampling and Testing Bitumen-Saturated
Felts and Woven Fabrics for Roofing and
Waterproofing
ASTM D412 Standard Test Methods for
Vulcanized Rubber and Thermoplastic
Elastomers-Tension
ASTM D903 Standard Test Method for Peel
or Stripping Strength of Adhesive Bonds
ASTM D1970 Standard Specification for Self-
Adhering Polymer Modified Bituminous
Sheet Materials Used as Steep Roofing
Underlayment for Ice Dam Protection
ASTM E96/E96M Standard Test Methods for
Water Vapor Transmission of Materials
ASTM E154 Standard Test Methods for Water
Vapor Retarders Used in Contact with Earth
Under Concrete Slabs, on Walls, or as
Ground Cover
Underwriters Laboratories, Inc. (UL) - UL 790
Standard Test Methods for Fire Tests of Roof
Coverings
Department of the Navy - NAVFAC TS-07111
General Services Administration (GSA)
PBS PCD 07121
PBS 07115
U.S. Department of Veterans Affairs (VA) - H-
08-1
U.S. Army Corps of Engineers (USACE) - CEGS-
07111-3-82
Federal Construction Guide Spec - FCGS-07111
American Railway Engineers Association,
Chapter 29
Amtrak Standard Specification 7.01
Conforms to California VOC regulations
APPROVALS
Consult manufacturer for current information
on approvals by code bodies and other
industry entities.
PHYSICAL PROPERTIES
See Tables 3 and 4.
5. Installation
STORAGE & HANDLING
Store all material inside in a dry space at tem-
peratures between 50 and 90 degrees F (10 and
32 degrees C). Do not store in direct sunlight. Do
not remove material from box until ready to use.
For cold weather applications, store Jiffy
Seal in a heated airspace at a temperature of
50 degrees F (10 degrees C) or higher for at
least 2 days prior to application. Remove only
the material that can be applied within 2 hours.
PREPARATORY WORK
Handle and store product according to man-
ufacturer’s recommendations.
Deliver materials in manufacturer’s original,
unopened, undamaged containers with identi-
fication labels intact. Store materials protected
from exposure to harmful environmental con-
ditions and at temperature and humidity con-
ditions recommended by the manufacturer.
Verify that site conditions are acceptable
for installation. Do not proceed with installation
until unacceptable conditions are corrected.
Surface Preparation
Prior to application, ensure that all surfaces
have, at a minimum, a smooth, steel-troweled
finish and are clean, free of sharp protrusions,
loose aggregate, dust, voids or spalled areas.
A broom finish is not permitted.
All exposed metal surfaces must be clean
and free of all paint, oil, coatings, rust or any
other contaminants. Wire brush and solvent
wipe all metal surfaces.
Repair all areas as needed before applying
Protecto Wrap primer.
CURING
Concrete must be cured a minimum of 28 days
for normal structural concrete and 14 days for
lightweight structural concrete.
Remove all forms as soon as possible to pre-
vent moisture entrapment. Grind uneven form
lines flush to the wall. Fill all tie holes.
Do not apply Jiffy Seal over frozen sub-
strates. For green concrete application, use
Jiffy Seal No. 80 Green Concrete Primer.
Consult Protecto Wrap Co. for green concrete
cure time recommendations.
Use form release agents that will not transfer
to the concrete or block walls. Concrete curing
compounds must be resin based and contain
no oil, wax or pigment. If Jiffy Seal membranes
are to be applied to a concrete or wood sur-
face where other curing compounds or wood
treatment is to be used, contact Protecto Wrap
for recommendations.
If additives have been placed in the con-
crete that could slow the dissipation of mois-
ture, contact Protecto Wrap Co. before instal-
lation of Jiffy Seal.
Masonry walls must not have struck joints.
Make sure all masonry joints on block and
brick walls are struck flush in order to provide
a smooth surface. On rough or porous sur-
faces, use a well-adhered mortar coat to pro-
vide a smooth surface.
Corners
For all inside horizontal corners, use cant strips
or fillets and Jiffy Seal 500. Wood or fiber cant
strips are not recommended.
After application of primer and Jiffy Seal
500, terminate the membrane a minimum of 3"
(76 mm) beyond the detail tape. The Jiffy Seal
must be applied flush to all angles of the inside
corner. If the design does not allow for a cant
strip at interior corners, consult Protecto Wrap
SHEET WATERPROOFING 07 13 00
Protecto Wrap Co.
®
TABLE 4 TYPICAL PHYSICAL PROPERTIES (PRIMER AND MASTIC)
No. 100 Primer No. 80 Primer JS160H Mastic
Adhesion to steel Excellent Excellent Excellent
Adhesion to concrete Excellent Excellent Excellent
Adhesion to membrane Excellent Excellent Excellent
Shelf life (min) 1 year 1 year 1 year
Tack-free time (minutes) 15 - 45 15 - 45 15 - 45
Coverage ft
2
/gal (m
2
/L) 150 - 200 (3.8 - 5) 175 - 250 (4.4 - 6.3) 22 - 50 (0.6 - 1.3)