Technical Specifications
P. 36
Simpson Hangers for PJI 40, 60, 80, and 90 Series
NOTES
1� Hangers that are marked by green
shading in tables require web stiffeners�
EACOM may require web stif feners for
hangers that are not marked by shading�
2� This table is for quick specification for
P3 Joist hangers� Refer to hanger manu-
facturer for additional design information�
3� MIT without web stiffeners on 3-1/2”
wide joists is limited to 1675 lbs� Alter-
natively, install web stiffeners for an
allowable load of 2305 lbs�
P3 Joist
Top Mount Face Mount Skewed 45
Load Load Load
Width Depth Top Mount
Uplift
(160)
Download
Face Mount
Uplift
(160)
Download
Skewed 45
Uplift
(160)
Download
DF/SP SPF DF/SP SPF DF/SP SPF
2-1/2
9-1/2 ITS2�56/9�5 105 1520 1150 IUS2�56/9�5 75 950 815 SUR/L2�56/9 195 2015 1735
11-7/8 ITS2�56/11�88 105 1520 1150 IUS2�56/11�88 75 1185 1020 SUR/L2�56/11 195 2305 1980
14 ITS2�56/14 105 1520 1150 IUS2�56/14 75 1420 1220 SUR/L2�56/14 195 2590 2225
16 ITS2�56/16 105 1520 1150 IUS2�56/16 75 1660 1425 SUR/L2�56/14 195 2590 2225
3-1/2
9-1/2 ITS 3�56/9�5 105 1520 1150 IUS3�56/9�5 75 1185 1020 SUR/L410 1120 2015 1735
11-7/8 ITS3�56/11�88 105 1520 1150 IUS3�56/11�88 75 1420 1220 SUR/L410 1120 2015 1735
14 ITS3�56/14 105 1520 1150 IUS3�56/14 75 1420 1220 SUR/L414 1520 2500 2150
16 ITS3�56/16 105 1520 1150 IUS3�56/16 75 1660 1425 SUR/L414 1520 2500 2150
18 MIT418 185 2305 1665 MIU3�56/18 180 3745 3220 SUR/L414 1520 2500 2150
20 MIT420 185 2305 1665 MIU3�56/20 180 4030 3465 SUR/L414 1520 2500 2150
22 HIT422 270 2875 1950 MIU3�56/20 180 4030 3465 -------------- not available --------------
24 HIT424 270 2875 1950 MIU3�56/20 180 4030 3445 -------------- not available --------------
TABLE 23
P3 Joist Strong-Tie Hangers
Top Flange Face Mount Skewed