Installation Guide

9
ZIP SYSTEM
®
SHEATHING AND TAPE
INSTALLATION MANUAL - ROOF
HUB 81824 REV 9/18
ZIP SYSTEM
®
SHEATHING
// GENERAL INFORMATION & COMPATIBILITY
FASTENERS
ZIP System
®
sheathing must be installed with code-approved
fasteners and by code approved methods. Please note, fasteners
used to install ZIP System
®
sheathing are not required to be
ring-shank, galvanized, stainless steel unless otherwise stated
by the local building code, designer of record or the engineer
of record.
COMPATIBLE SUBSTRATES
ZIP System
tape is compatible with dimensional lumber
(treated and untreated), OSB, plywood, house-wraps, PVC,
vinyl and metal substrates. Please note, the ZIP System
®
panel
substrate must be dry to the touch and free of any dirt or debris
at the time of tape installation.
SEALANTS
ZIP System
®
sheathing and tape is compatible with butyl,
polyurethane and 100% silicon sealants. When using 100%
silicon sealants over ZIP System
tape use a primer such as
3M Hi-Strength 90 or rub the tape with an acetone cleaner.
Please note, when installing ZIP System
tape over sealants the
sealants must be completely cured before the tape is installed.