Datasheet
BCM SENSOR TECHNOLOGIES BVBA
Brechtsebaan 2
B-2900 Schoten - Antwerpen, BELGIUM
Industriepark Zone 4,
Tel.: +32-3-238 6469
Fax: +32-3-238 4171
website: www.bcmsensor.com
email: sales@bcmsensor.com
Technical Data
The listed specifications are subject to change without prior notice.
parameters
safe load limit
ultimate overload
output sensitivity at full scale
zero unbalance
non-linearity
hysteresis
repeatability
excitation (supply voltage)
capacity
max. excitation voltage
input resistance
output resistance
insulation resistance
storage temp. range
operating temp. range
compensated temp. range
temp. coefficient of sensitivity
load cell body material
creep error (30 min.)
sealing
mechanical interface
electrial interface
environment protection
unit weight
temp. coefficient of zero
model
specifications
150
300
1.0 ± 0.1
± 5
± 0.05
± 0.05
± 0.03
5, ..., 10
0.3, 0.5, 0.7, 1, 3, 5, 7, 10, 30, 50, 70
15
1060 ± 50 (standard), ± 30410
1000 ± 50 (standard), 350 ± 10
≥ 2000@50 Vdc
-35 ~ +80
-20 ~ +60
-10 ~ +50
± 0.01
aluminum alloy
± 0.05
potted
IP 65
~ 35
± 0.01
units
%fs
%fs
mV/V
%fso
%fs
kg
Vdc
Vdc
Ω
Ω
MΩ
°C
°C
°C
%fs/°C
%fs
g
%fs/°C
166H 169H
20, 30, 50, 70, 100, 200
200
2.0 ± 0.2
± 1.5
%fs
%fs
17-4PH stainless steel
Φ3.8 mm, 4-conductor shield, PVC jacket, 0.25 m
refer to the dimensions on the datasheets
Model 166H/169H
Single Point Load Cells