Installation Guide

Vented space
Figures 20 & 21: Cold Roof Systems
Figure 20: Gable Roof
Figure 21: Shed Roof
Double starter
course
Screen
Rigid insulation
Decking
Vented space
Certi-label shakes and shingles are an
excellent roofing material for cold weather
areas that experience heavy snowfall and
severe temperature extremes. Certi-label
shakes and shingles offer the advantages of
durability, superior wind resistance and good
thermal and acoustical properties. As with
any other roofing material, however, their
best performance depends upon proper
design, sound construction practice and
correct installation.
In cold weather areas and particularly in
mountain regions that experience very heavy
snowfall, the cold roof - or vented roof
system - is recommended (Figures 20 & 21).
The principle of this system is to allow a
constant flow of cold air above the insulation
but below the roofing material. With other
roofing systems, ice buildup along the eaves
can be a problem. Heat escapes from the
insulation and melts snow, which runs down
the roof to the cold overhangs where it
freezes, causing water to back up and
sometimes penetrate the roof systems. A
properly installed, vented cold roof
eliminates this problem. Venting space
should be sufficient to allow a free flow of air
from eave to ridge.
There are a number of important
considerations that influence roof
performance in areas of heavy snowfall,
particularly mountain regions.
Design, of course, is very important. The
steeper the roof the better the performance.
Chimneys should be located at the ridge or
gable ends away from possible snow
pressure on the slopes. Plumbing pipes
should be located on inside walls and should
be extended between the rafters and vented
at the ridge. If this is not practical then
plumbing vent pipes should be galvanized
iron, well anchored inside the roof. (Plastic
vent pipes extending through the roof may
be dislodged by sliding snow.)
COLD ROOF SYSTEM DETAILS
Certi-label shakes or shingles
(applied per specification)
Certi-label shakes or shingles
(applied per specification)
Ridge vent
Cap
Screen
Trim
Spaced
sheathing
Rafter
Insulation
17