Table 4164-1 MPPT MODE†
`
Value
Description
PV_Uset
0x0001
U-SET MPPT MODE (includes MPPT ENABLED (On) FLAG i.e. if
0x0000 MPPT mode is OFF)
DYNAMIC
0x0003
Slow Dynamic Solar Tracking (old Solar 1 O & P )
Legacy P&O
0x0009
Legacy P & O sweep mode
SOLAR
0x000B
Fast SOLAR track (old PV Learn mode)
MICRO HYDRO
0x000D
Micro Hydro mode (similar to Legacy P&O)
WIND TRACK
0x0005
Wind Track Mode
WIND LEARN (future mode)
0x0007
Wind Learn Mode (not implemented as of May 2011)
PV COMBO 1
0x000F
PV COMBO 1
RESERVED
0x0011
RESERVED
BOOST CHRG
0x0013
Boost Charge Mode (Lower to Higher Voltage, Unimple-
mented as of May 2011)
†Bit 0 is the ON/OFF (Enable/Disable) Table shows modes as ON
NOTE: MPPT MODE will automatically revert to OFF during mode change
Table 4207-1 LED Mode
Name
Value
Description
All Off
0
No LED activity except on startup
Rick Mode
1
Minimal Activity: Remote Yellow LED indicates Current
Limiting or FET Temperature Limit.
Blinky
2
All LEDs Active: Lightshow!
MNGP Red LED : MNGP->Classic MODBUS active
LED 1
3
Status Mode:
MNGP Green LED = Battery Full (Float)
Classic Red LED = Aux 1 Active.
Classic Yellow LED = Aux 2 Active
Classic Blue LED = Unimplemented
LED 2
4
Unimplemented
LED 3
5
Unimplemented