Manual

38 | P a g e
the submenu where you will be able to change the parameters of the unit. To get out of the submenus push
MAIN MENU, this will take you out of the submenus one at a time every time you push it. See page 44
for entire Menu Map.
Viewing Other MidNite Products on the Display
The Classic is able to view other products or Classics connected to the network. For example: the
MidNite Solar Clipper. To view other products or Classics connected to the Classic network, go to the
Status screen and press the UP and DOWN arrows to scroll between the addresses of the different items.
The Classic is address 10 and labeled. CLASSIC
Connecting Classic to Two MNGPs/Network cable
The Classic can be controlled with two MNGPs at the same time. This will help when the Classic is in a
shop and there is a considerable distance between the Classic and the controlling point (office, inside
house, garage etc.). Instead of going to the Classic to check status or to change a setting, the user can run
a cable to the controlling point and see the Classic in a second MNGP. The cable is a six wire phone
cable. Connect one side of the extension cable to the jack in the Classic labeled SLAVE/OUT and the
other end to the second MNGP. Since the Classic transmits power and data signals through the phone
cable to the MNGP the length of the cable is limited to 100ft.
MidNite Solar only offers a 3ft as an optional
accessory. If you are making your own cable
be sure be sure to insert cable end all the way
into the phone terminal to get a good contact.
Use the phone crimping pliers to crimp both
ends of the cable.
We recommend using flat phone cable for extension, just
because it is easier to work with. Use the two pictures above as reference. Make sure the color and
position of the wires are as shown in the diagram below. Use terminal connector tab as reference.