Manual
36 | P a g e
Aux 2 Function. Output/Input
OUTPUT = 12V/0V Signal
FLOAT LOW Aux2 off when in Float
FLOAT HIGH Aux2 on when in Float
DAY LIGHT Aux2 on at dawn off at dusk
NITE LIGHT Aux2 on at dusk off at dawn
CLIPPER CONTROL PWM Control for Clipper
Pv V ON LOW PWM sig below Pv in setpoint
Pv V ON HIGH PWM sig above Pv in setpoint
TOGGLE TEST Aux2 cycled 1 sec interval
OPPORTUNITY LO PWM divert rltv chg state lo
OPPORTUNITY HI PWM divert rltv chg state hi
DIVERSION LO PWM Divert on Bat voltage lo
DIVERSION HI PWM Divert on bat voltage hi
To set/ change threshold voltage as well as time do the following:
When in the function you wish to use press the right soft button
This will take you to the VOLTS menu here is where you set your threshold voltage
Use the left and right arrow keys to navigate through the options
Use the up and down arrow keys to raise or lower the threshold voltage
To change the time press again the right soft button to get to the TIME menu
In this menu do the same as you did in the VOLTS menu, until desired adjustments are made
Press ENTER to save
Setting the MNGP features, Access the Version of software and Restore
factory defaults
The Classic comes with an integrated ―MidNite Graphics Panel‖ (MNGP), which is the primary interface
to the Classic. Setting up contrast, backlight and volume its simple just follow the steps below.
Push the Main Menu button.
Scroll left or right to highlight ―Misc‖ and push the Enter button.
Use the left and right arrow keys to select the feature to set and press the Enter button
Press the up and down buttons to adjust
Press Enter to save
Use diagram below for MNGP reference. Figure 2.8