Opportunity Hi
This mode is PWM based and will PWM Aux 2 when the Classic gets within a certain range of the voltage set
points for each charging stage (V High) and stop when it gets to a low set point (V Low). These set points are user
adjustable and will allow the Absorb, Float and EQ timers to continue to run. You will adjust these set points to
negative numbers and the numbers are an offset from the voltage set point. For example a -.2 would turn Aux 2 on
2 tenths of a volt below your set points. This mode will allow you maximum diversion while maintaining your 3
stage charging.
Diversion Lo
This mode is PWM based and is just reverse logic of Diversion Hi. It would be comparable to using the NC con-
tacts of the relay used in Diversion Hi. It can be used that way with a solid state relay and NC contacts to do diver-
sion above a set voltage.
Diversion Hi
This mode is PWM based and will PWM Aux 2 at a set point based on battery voltage (V High) and stop it at
another set point based on battery voltage (V Low).
Aux 1 Function
OUTPUT = Relay or 12V/0V Signal jumper selectable
Aux 1 has the relay so Diversion functions must operate slowly
VENT FAN LOW Aux1 on below setpoint
VENT FAN HIGH Aux1 on above setpoint
FLOAT LOW Aux1 off when in Float
FLOAT HIGH Aux1 on when in Float
CLIPPER CONTROL PWM Control for Cipper
DAY LIGHT Aux1 on at dawn off at dusk
NITE LIGHT Aux1 on at dusk off at dawn
TOGGLE TEST Aux1 cycled 1 sec interval
Pv V ON LOW Aux1 on below Pv in setpoint
Pv V ON HIGH Aux1 on above Pv in setpoint
OPPORTUNITY LO Divrt based on chrg state lo
OPPURTUNITY HI Divrt based on chrg state hi
LOW BAT DISC Disc load based on bat volt
DIVERSION Slow Diversion control