Manual
25 | P a g e
Connecting the Classic to the Clipper
Not Yet Available Please email customerservice@midnitesolar for status
updates on the Clipper.
Maximum and Minimum Wire Size
The Classic DC terminal connector will accept wire from #14-#4 AWG
Commissioning the Classic
The Classic will enter into the setup wizard upon initial power up. If the Classic does not enter into the
setup wizard or you want to enter the wizard at any time follow these steps to get into the setup wizard.
Press the Main Menu button.
Scroll Left or Right until Wizard is highlighted and press the Enter button.
Follow the on screen instructions through to the end.
Using the Classic Setup Screen's
The Classic setup wizard will walk you through the set up process. Below is a description of the steps.
DO YOU WANT PASSWORD
ENABLED?
PASWORD WILL BE 142
YES NO
Sets the password On Classic Settings
CONNECTED TO
CLASSIC 150
Tells you which classic model it is
IS THIS A
GRID TIED SYSTEM
(BATTERY BACKUP)
YES NO
This menu will determine how to treat batteries
differently. sealed batteries lower voltage for
grid tied
TIME DATE
24:00:00 01/10/2010
Set time and date, this is important because
Classic will automatically know at what time to
wake up and go to sleep mode
(Sunrise/sunset using Astronomical formulas)
BATTERY CHEMISTRY
FLOODED LEAD ACID
ENTER
Sets up battery temp compensation and absolute
maximum charge voltages regardless of temp
BATTERY BANK VOLTAGE
48
Selects between different voltage configurations
on the system, increments of 12 volts (12v, 24v,
36v, 48v, 60v, 72v)