User`s manual

Spec*Edge Version 3.9
June 11, 2008
Analysis - 2
The analysis will be accomplished on each sheet in the order scanned as fast
as the computer can do the mathematics. As each sheet is analyzed the
OK/Warn/Fail lights will illuminate for the sheet that is indicated at the top right of
the Operator Screen.
OK/Warn/Fail Area (Figure 1): This panel indicates each of the measurements
completed and the results as specified for the selected test in the setup
screen.
Green = OK
Yellow = Warn
Red = Fail
Summary Buttons:
Summary Button
Shows
the operator the
worst condition indicated on the
OK/Warn/Fail panel. Clicking on this button
brings up the information summary screen
(Figure 1). From this screen the operator
may elect to print individual scan results.
3.0 Getting More Analysis:
When the operator selects the <Scan> button. Spec*Edge
will automatically
scan, analyze and report the findings, as determined by the setup specifications, to
the operator. Once the scan is complete the operator may place the second sample
(if required) on the scanner and click on the <Scan> button to start the second sheet
in the group. The analysis will be accomplished on each sheet in the order scanned
as fast as the computer can do the mathematics. As each sheet is analyzed the
OK/Warn/Fail lights will illuminate for the sheet shown in Figure 1 that is
indicated at the top right of the Operator Screen.
Show the number of pockets (sheets) and the
progress of each.
Empty
Scanning
Complete
Invalid
Unknown
As each sample is analyzed the operator may view the results of each measurement
by: