TABLE OF CONTENTS SAFETY WARNINGS.....................................................................................................................................................3 SAFETY INSTRUCTIONS ............................................................................................................................................3 PRODUCT APPLICATION ...........................................................................................................................................
SAFETY WARNINGS • • All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit. The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to observe precautions could result in injury to people or damage to property. ! This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
PRODUCT APPLICATION CONSTRUCTION • • • • • • The water purifier is designed to mount horizontally. A drain port on the chamber aids in draining of the purifier. The water purifier chamber is passivated and electropolished type 316 Stainless Steel. The ballast housing is a combination of Stainless Steel Type 304 and Aluminum Alloy. Coated chambers are available for uses with special applications, consult Factory.
INSTALLATION LOCATION 1. 2. 3. 4. 5. 6. 7. The water purifier is intended for indoor use only. The water purifier should be protected from the elements and from temperatures below freezing. The ambient temperature, in the area surrounding the water purifier, should be between 33 F and 100 F. Electrical power supplied to the water purifier MUST match power requirements listed on the water purifier. Use of a voltage surge protector is recommended.
INSTALLATION 1. Remove water purifier from shipping carton. Inspect water purifier, power cord and plug for damage. Do not operate if there is any damage to the purifier, power cord or plug. Models MP13A through MP22A are shipped with the lamps already installed, while the MP36C and MP49C lamps are packed separately. Keep the lamp aside for installation once the purifier has been properly installed. 2. Units occasionally experience damage in shipment due to the fragility of the quartz sleeve.
RECOMMENDED OPTIONS 1 . Guardian™ Ultraviolet Monitor: Visually indicates the level of germicidal ultraviolet energy that penetrates the quartz sleeve and the water within the water purifier. The ultraviolet monitor is capable of operating an optional audio alarm and/or solenoid valve. The ultraviolet monitor will detect reduction of ultraviolet levels due to: • Fouling or deposits on the quartz sleeve.
MAINTENANCE The water purifier is designed to operate with a minimal amount of maintenance, providing the water quality does not exceed maximum concentration levels, see “Water Quality” in the “Product Application” section. Ordinary maintenance consists of; • Lamp replacement is recommended every 10,000 hours of operation, approximately 12 months of continuous service. • Cleaning of the quartz sleeve, when conditions warrant.
LAMP INSTALLATION OR REPLACEMENT Figure 3 - Lamp Replacement 1. 2. 3. 4. 5. 6. 7. Step 2 - Remove End-Cap Step 3 - Withdraw Lamp Step 4 & 5 - Remove Sockets Step 6 - Remove Lamp Disconnect power to water purifier. Remove both easy-off end caps by pulling each cap off static gland nut. Slide each end cap along the wire away from the socket. Carefully withdraw lamp approximately 2 inches from chamber while feeding lamp socket and lead wire on opposite end of chamber.
QUARTZ SLEEVE CLEANING OR REPLACEMENT Figure 4 - Quartz Sleeve Cleaning or Replacement Step 4 - Remove Gland Nuts 1. 2. 3. Step 5 - Remove Washer & O-Ring Step 6 - Remove Quartz Sleeve Disconnect power to water purifier. Shut off water supply to water purifier via inlet and outlet shut off valves. Drain chamber by removing drain plug.
REPLACEMENT ! 1. 2. 3. 4. • • • 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. OF BROKEN QUARTZ SLEEVE CAUTION: Broken Quartz is SHARP. It is recommended that protective goggles and gloves are worn when handling broken quartz sleeves. Disconnect power to water purifier. Shut off water supply to the water purifier via the inlet and outlet shut off valves. Drain the chamber by removing the drain plug.
OPTIONAL GUARDIAN™ ULTRAVIOLET MONITOR SENSOR PROBE CLEANING Figure 5 - Ultraviolet Monitor and Sensor Probe If after cleaning the quartz sleeve, there is no significant improvement in the ultraviolet intensity, as shown on the intensity meter, it may be necessary to clean the Ultraviolet Monitor's sensor probe. The sensor probe body mounts in a fitting, located in the center of the disinfection chamber, and protrudes into the chamber. 1. Disconnect power to the water purifier. 2.
TROUBLESHOOTING ! CAUTION: Always disconnect power to the water purifier, before performing any service. IMPORTANT: This unit is to be serviced ONLY by qualified, and appropriately licensed, personnel. Table 3 - Troubleshooting Problem Purifier not operating. Possible Cause Corrective Action No electrical power… Verify that the purifier is connected to a live power source. Ballast Disconnect the purifier from utility power. Replace lamp.
TECHNICAL SPECIFICATIONS Table 4 - Technical Specifications Model: MP13A MP16A MP22A MP36C MP49C Flow Rate (GPM): 2 3 6 12 20 Inlet\Outlet Size: 1 3 3 /4"m NPT 1"m NPT 1- 1/2"m NPT Number of Lamps: 1 1 1 1 1 Lamp Model No.
OPTIONAL ACCESSORIES Optional accessories are available for operation at 120v 60Hz or 220v 50Hz, unless specified. Please specify. Consult Factory for 12v DC or other special input power requirements.
REPLACEMENT PARTS MightyPure™ Models MP13A, MP16A & MP22A Figure 6 - Exploded View MP13A, MP16A & MP22A 16
Table 6 - Replacement Parts MP13A, MP16A & MP22A ITEM NO. DESCRIPTION QTY MP13A PART NO. QTY MP16A PART NO. MP22A QTY PART NO.
REPLACEMENT PARTS MightyPure™ Models MP36C & MP49C Figure 7 - Exploded View MP36C & MP49C 18
ITEM NO. DESCRIPTION QTY MP36C PART NO. MP49C QTY PART NO.
USER ASSISTANCE Atlantic Ultraviolet Corporation makes every effort to ensure that the MightyPure™ Ultraviolet Water Purifiers are products of superior quality and workmanship. This manual describes the installation, operation and maintenance of the MightyPure™ Ultraviolet Water Purifiers. Please read and become familiar with the contents of this manual before installing or using this unit.