Unit installation
19
using the LED display
If an LED bulb does not light after you replace a UV lamp, you
need to verify the electrical output of the ballast connected to that
specific UV lamp. This is done by testing the ballast open circuit
voltage. This should be done by an electrician or qualified
facilities personnel. Follow these recommended procedures:
1. Turn power “off” to the UV unit.
2. Remove the socket cover.
3. Identify the “faulty” UV lamp which corresponds to the
number on the LED display.
4. Remove the lamp socket(s) from the “faulty” UV lamp base.
5. Use a voltmeter and set an operating range at >700 VAC.
6. Measure the open circuit voltage:
For single-ended (SE) UV lamps: connect the voltmeter across
the receptacles of the lamp socket.
For double-ended (DE) and high temperature (HT) UV
lamps: connect one end of the voltmeter to one end of the lamp
socket and the other end of the voltmeter of the opposite end of
the lamp socket.
7. Turn power “on” to the UV unit.
8. Record the reading.
9. Turn power “off.”
10. Listed below please find the open circuit voltages for the
various ballasts:
If the voltage reading is zero or a number above or below the
acceptable ranges, this indicates a ballast fault, and the ballast
connected to the “faulty” UV lamp must now be replaced.
If the voltage reading is within acceptable ranges but the LED
does not light, the LED board has failed and needs to be replaced.
Refer to the Replacement Parts Lists in the back of this manual to
identify the proper ballast and/or LED part number.
UV Lamp Operational Display Panel
Ballast type
120 Volt Electronic 240 Volt Magnetic 240 Volt HE
550-650 575-675 450-660
CAUTION! AvoidCAUTION! Avoid
CAUTION! AvoidCAUTION! Avoid
CAUTION! Avoid
touching the lamptouching the lamp
touching the lamptouching the lamp
touching the lamp
tip after you re-tip after you re-
tip after you re-tip after you re-
tip after you re-
move the lampmove the lamp
move the lampmove the lamp
move the lamp
socket. This is asocket. This is a
socket. This is asocket. This is a
socket. This is a
shock hazard.shock hazard.
shock hazard.shock hazard.
shock hazard.