Instruction manual

Upstream Instruction Manual
Released on 1-May-14 – R800001Q Page 7 UV Pure Technologies Inc. © 2014
WARNING - Improper connection of the equipment-grounding conductor can
result in a risk of electric shock. Check with a qualified electrician or service
representative if you are in doubt whether the unit is properly grounded. Do not
modify the plug provided with this unit; if it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
GROUND-FAULT CIRCUIT-INTERRUPTER
To comply with National Electrical Code, NFPA 70, the circuit where the UV
unit(s) is connected must be protected by a ground-fault circuit-interrupter
(GFCI). UV Pure recommends the use of Hubbell GFICs.
WARNING: Potential Shock Hazard
Use only a grounded electrical outlet when connecting the unit to a
power source. If an extension cord is necessary, the cord should
contain a ground and be rated for the same amperage as the unit or
combined units. Do not plug in unit if water is present on the unit.
WARNING: Ultraviolet Light Hazard
The lamps in the unit emit ultraviolet (UV) light that can cause
permanent damage to the skin & eyes. Never look at the lamp when
it is operating. Do not plug the unit in unless it is properly secured to
a wall (see Installation Instructions) and the front panel and ballast
enclosure door are secure. Do not open the front panel or perform any
service unless the unit has been unplugged. Never look into the unit or
place any exposed skin into the illuminated areas when it is operating.
Do not operate a unit that has been damaged or missing any
components or safety devices.
Note that service to the unit does not require the removal of the side
aluminum panels or aluminum endplates and they must remain
assembled. The Upstream unit is not intended for use by young
children or infirm persons without supervision. Young children should
be supervised to ensure that they do not play with the Upstream unit.
Parts Included
Upstream UV system complete with integral wall brackets (1)
Ultraviolet lamps (2) – installed within the unit
Instruction manual (1)
Power cord (1) (located within packaging)
Stainless flexible hoses (2) (hoses located within packaging)
External dry contact for remote monitoring
20’ of Flexible hose for connection of purge valve to drain
Transient Voltage Surge Suppressor (TVSS)/Surge Protective Device
(SPD) for North American markets (120Vac systems)
Optional - Pre-treatment sediment and or carbon filter to remove water
particles, odor or trace chemicals for improved taste.
- Automatic shutoff solenoid valve (included in bundled systems).
- Remote Wireless Monitor with 9V battery (1) (in bundled systems
only).
UVUVUV