LIFT QUARTZ SLEEVE
OUT OF THE UNIT
REMOVE TOP
O-RING
REMOVE & SUPPORT
TOP QUARTZ
SEAL ASSEMBLY
DISCONNECT
FLEX. HOSE
REMOVE BOTTOM
O-RING
REMOVE COVER:
PULL OUTWARDS
AND DOWN
REMOVE BOTTOM
QUARTZ SEAL ASSY.
Figure 4D
Step 2: If the quartz is still dirty, use a scale remover such as CLR or Lime Away
and apply it to the inside of the quartz sleeve. Citric acid, available at a drug
store, can also be used. Always flush with clean water afterwards.
Step 3: Once the quartz is clean, reassemble the unit (see Figure 4E). Replace
any seals that appear to have been damaged.
Step 4: If the quartz is still not clean, it requires replacement. This is done by
removing the bottom quartz seal assembly (see Figure 4D).
Step 5: Remove the bottom cover and then the bottom quartz seal assembly by