Technical data
9.4.Service life of the plane, revisions and inspection of the engine
Use the liquid with anti corrosive ingredients prescribed for  the  block of engines from 
aluminum base alloys. Do not use the refrigerating liquid in bigger concentration, it can be 
detrimental for individual parts of the refrigerating system.
The refrigerating liquid density should be checked before the beginning of winter. Fill the 
refrigerating liquid to the tank.
ATTENTION!
Do not open the tap of the refrigerating liquid tank in hot state. You can get burnt 
easily.
While letting out the refrigerating liquid it is necessary to open the tap of the tank and screw 
out the low tightening screw / with the impermeable ring / of the water pump. Then it is 
necessary to release the low pipe of the cooler of the refrigerating liquid / which is located 
lower than the engine / to let the old refrigerating liquid leak out, after letting it out, put the 
pipe back on the cooler and tighten the buckle carefully. While exchanging the refrigerating 
liquid it is also necessary to exchange the tamping under the low tightening ring  of the water 
pump. This screw is tightened by the moment of 10Nm. 
9.4. Service life, revision and engine revisions
The   producer   prescribes   the   engine   revisions   after   25,50,100   and   200   hours   with   the 
tolerance + - 10hours. These tolerances can not be added. The service after 100 hours is also 
done at least once a year no matter how many flight hours had been reached. 
The revision after 25 hours is performed on a new engine and on engine after general 
overhaul.
The   extension   of   prescribed   revisions   is   introduced   in   the   original   handbook 
´´Wartungshandbuch fur Rotax Motor Type 912 Serie ´´, which is a part of the delivery. It is a 
shop  handbook   which   is   not   indicated   for  instant user.  There   is   no   translation   of   this 
handbook and its producer suppose that the prescribed maintenance of the engine will be 
performed by the authorized technician. 
The revision after 25 hours of operating is combined with the exchange of the oil and the oil 
filter. The service of the engine after 50 hours is not recommended by the producer, with the 
exception for the engine with the fuel AVGAS, when is also necessary to exchange the 
oil after 50 hours of operating.
47