Specifications
Table Of Contents
- iXon Ultra
- SAFETY AND WARNINGS INFORMATION
- SAFETY AND WARNINGS SYMBOLS
- MANUAL HANDLING
- SHIPPING AND STORAGE PRECAUTIONS
- SECTION 1 - INTRODUCTION TO IXON ULTRA HARDWARE
- 1.1 - TECHNICAL SUPPORT
- 1.2 - DISCLAIMER
- 1.3 - TRADEMARKS AND PATENT INFORMATION
- 1.4 - COMPONENTS
- 1.4.1 - Camera description
- 1.4.2 - Camera Power Supply Unit
- 1.4.3 - SOFTWARE
- 1.5 - SPECIFICATIONS
- 1.6 - ACCESSORIES
- 1.7 - SAFETY PRECAUTIONS AND MAINTENANCE
- 1.7.1 - Care of the camera
- 1.7.2 - Regular checks
- 1.7.3 - Annual electrical safety checks
- 1.7.4 - Replacement parts
- 1.7.5 - Fuse replacement
- 1.7.6 - Working with electronics
- 1.7.7 - Condensation
- 1.7.8 - Dew Point graph
- 1.7.9 - EM Gain ageing
- 1.7.10 - Minimizing particulate contamination
- 2.1 - INSTALLING THE HARDWARE
- 2.1.1- PC requirements
- 2.2 - INSTALLING ANDOR SOLIS SOFTWARE - WINDOWS O/S(XP/VISTA/SEVEN)
- 2.3 - NEW HARDWARE WIZARD
- 2.5 - WATER PIPE CONNECTORS
- 2.6 - MOUNTING POSTS
- 2.7 - COOLING
- 2.8 - START-UP DIALOG
- 3.1 - EMCCD OPERATION
- 3.1.1 - Structure of an EMCCD
- 3.1.2 - EM Gain & Read Noise
- 3.1.3 - EM Gain ON vs EM Gain OFF
- 3.1.4 - Multiplicative Noise Factor and Photon Counting
- 3.1.5 - EM Gain dependence and stability
- 3.1.6 - RealGain: Real and Linear gain
- 3.1.7 - EM Gain Ageing: What causes it and how is it countered?
- 3.1.8 - Gain and signal restrictions
- 3.1.9 - EMCAL
- 3.2 - COOLING
- 3.2.1 - Cooling options
- 3.2.2 - Heat generated in the EMCCD
- 3.2.3 Heatsink “hot side“ temperature
- 3.2.4 - Fan settings
- 3.3 - SENSOR READOUT OPTIMIZATION
- 3.3.1 - Sensor Pre-amp options
- 3.3.2 - Variable Horizontal Readout Rate
- 3.3.3 - Variable Vertical Shift Speed
- 3.3.4 - Output amplifier selection
- 3.3.5 - Baseline Optimization
- 3.3.5.1 - Baseline Clamp
- 3.3.6 - Binning and Sub Image options
- 3.4 - ACQUISITION OPTIONS
- 3.4.1 - Capture Sequence in Frame Transfer (FT) Mode
- 3.4.1.1 - Points to consider when using FT Mode
- 3.4.2 - Capture Sequence in Non-Frame Transfer Mode (NFT) with an FT EMCCD
- 3.4.2.1 - Points to note about using an FT EMCCD as a standard EMCCD
- 3.4.3 - Capture Sequence for Fast Kinetics (FK) with an FT EMCCD
- 3.4.3.1 - Points to consider when using Fast Kinetics mode
- 3.4.4 - Keep Clean Cycles
- 3.5 - TRIGGERING OPTIONS
- 3.5.1 - Triggering options in Frame Transfer (FT) mode
- 3.5.1.1 - Internal Triggering (FT)
- 3.5.1.2 - External Triggering (FT)
- 3.5.1.3 - External Exposure (FT)
- 3.5.2 - Triggering options in Non-Frame Transfer (NFT) mode
- 3.5.2.1 - Internal (NFT)
- 3.5.2.2 - External & Fast External (NFT)
- 3.5.2.3 - External Exposure (NFT)
- 3.5.2.4 - Software trigger (NFT)
- 3.5.3 - Trigger options in Fast Kinetics (FK) mode
- 3.5.3.1 - Internal (FK)
- 3.5.3.2 - External (FK)
- 3.5.3.3 - External Start (FK)
- 3.6 - SHUTTERING
- 3.7 - COUNT CONVERT
- 3.8 - OPTACQUIRE
- 3.8.1 - OptAcquire modes
- 3.9 - PUSHING FRAME RATES WITH CROPPED SENSOR MODE
- 3.9.1 - Cropped Sensor Mode Frame Rates
- 3.10 - ADVANCED PHOTON COUNTING IN EMCCDs
- 3.10.1 - Photon Counting by Post-Process
- 3.11 - SPURIOUS NOISE FILTER
- 4.1 - EMCCD TECHNOLOGY
- 4.1.1 - What is an Electron Multiplying CCD?
- 4.1.2 - Does EMCCD technology eliminate Read Out Noise?
- 4.1.3 - How sensitive are EMCCDs?
- 4.1.4 - What applications are EMCCDs suitable for?
- 4.1.5 - What is Andor Technology's experience with EMCCDs?
- 4.2 - EMCCD SENSOR
- 4.3 - VACUUM HOUSING
- 4.3.1 - Thermoelectric cooler
- 4.4 – USB 2.0 INTERFACE
- 4.5 - OUTGASSING
- 4.6 - EXTERNAL I/O
- 4.7 - SIGNAL DIAGRAMS
- 4.8 - CAMERALINK
- SECTION 5: TROUBLESHOOTING
- 5.1 - UNIT DOES NOT SWITCH ON
- 5.2 - SUPPORT DEVICE NOT RECOGNISED WHEN PLUGGED INTO PC
- 5.3 - TEMPERATURE TRIP ALARM SOUNDS (CONTINUOUS TONE)
- 5.4 - CAMERA HIGH FIFO FILL ALARM
- 5.5 - USE OF MULTIPLE HIGH SPEED USB 2.0 I/O ON ONE CAMERA
- A.1 - GLOSSARY
- A.1.1 - Readout sequence of an EMCCD
- A.1.2 - Accumulation
- A.1.3 - Acquisition
- A.1.4 - A/D Conversion
- A.1.5 - Background
- A.1.6 - Binning
- A.1.7 - Counts
- A.1.8 - Dark Signal
- A.1.9 - Detection Limit
- A.1.10 - Exposure Time
- A.1.11 - Frame Transfer
- A.1.12 - NOISE
- A.1.12.1 - Pixel Noise
- A.1.12.1.1 - Readout Noise
- A.1.12.1.2 - Shot Noise
- A.1.12.1.2.A - Shot Noise from the Signal
- A.1.12.1.2.B - Shot Noise from the Dark Signal
- A.1.12.1.3 - Calculation of Total Pixel Noise
- A.1.12.2 - Fixed Pattern Noise
- A.1.13 - Quantum Efficiency/Spectral Response
- A.1.14 - Readout
- A.1.15 - Saturation
- A.1.16 - Scans (Keep Clean and Acquired)
- A.1.17 - Shift Register
- A.1.18 - Signal To Noise Ratio
- B - MECHANICAL DIMENSIONS
- C - DECLARATION OF CONFORMITY
- D - HARDWARE AND SOFTWARE WARRANTY SERVICE
- D.1 - SERVICE DESCRIPTION
- D.2 - Access to Service
- D.3 - Hardware Remediation
- D.4 - Software Remediation
- E - THE WASTE ELECTRONIC AND ELECTRICAL EQUIPMENT REGULATIONS 2006 (WEEE)

Version 1.1 rev Jan 2013
Page 79
iXon Ultra
, Features and Functionality
3.8 - OPTACQUIRE
OptAcquire is a unique control interface, whereby a user can conveniently choose from a predetermined list of set-
up congurations, each designed to optimize the camera for different experimental acquisition types, thus removing
complexity from the extremely adaptable control architecture of the iXon Ultra. The control architecture of the iXon Ultra
is extremely tuneable, meaning the camera can be adapted and optimized for a wide variety of quantitative experimental
requirements, ranging from fast single photon counting through to slower scan, 16-bit dynamic range measurements.
However, successfully optimizing EMCCD technology is not a trivial exercise, with various set-up parameters directly
inuencing different camera performance characteristics.
OptAcquire has been designed as a unique interface whereby a user can choose from a predetermined list of eleven
camera set-up congurations. A variety of set-up parameters are balanced behind the scenes through the OptAquire
menu. Furthermore, advanced users may wish to create their own additional OptAcquire conguation. iXon Ultra control
parameters include:
• EM Gain – This parameter has a direct bearing on both sensitivity and dynamic range.
• Vertical clock speed – Flexibility in this parameter is critical to optimizing the camera for lowest noise, fastest
speed, minimal frame transfer smear or maximum pixel well depth.
• Vertical Clock Amplitude – Can be used to compensate charge transfer when the sensor is being ‘over-
clocked’ and also to reduce charge leakage into the image area when there is saturated signal in the frame
transfer storage area (e.g. when combining very short exposure with a slow readout speed).
• Horizontal readout speed – Ranging between 17 MHz and 0.08MHz. 17MHz for faster frame rates, 0.08MHz
for best dynamic range.
• Pre-amplier gain – Trading off reduced digitization noise versus accessing full pixel well depth.
• EM / Conventional amplier – To choose between ultra-sensitive EMCCD operation or traditional high dynamic
range CCD operation, the latter recommended for relatively ‘brighter’ signals or when it is possible to apply long
exposures to overcome read noise oor.
• Frame Transfer (overlap) – Overlapped readout is used to achieve 100% duty cycle, ideal for fastest frame rate
measurements without switching exposure time between frames. This mode should be deselected for time-
lapse experiments.