Installation manual
G:\InDATA\manuals\OM-KE E V1.02 August 17, 2012
Page 13
KING KE 1107
INSTALLATION INSTRUCTIONS cont.
MINIMUM CLEARANCES for KE1107 and KEJ1107
Residential Installations A B C D E F J
Roof exit, parallel and corner. No fan kit required. 16”
410mm
9”
230mm
27”
690mm
16.5” *
420mm
14”
360mm
25” *
640mm
72”
Roof exit, reduced side. Use side shields 10”
254mm
9”
230mm
21”
534mm
16.5”
420mm
72”
Roof exit, reduced corner. Use side shields and either fan kit or rear 
shield.
6”
153mm
17”
433mm
72”
Roof exit, close clearance. Use side shields, and either fan kit or 
rear shield.
10”
254mm
6”
153mm
21”
534mm
13.5”
343mm
72”
Wall exit, parallel and corner. No fan kit required. 16”
410mm
11”
230mm
27”
690mm
18.5” *
470mm
14”
360mm
25” *
640mm
72” *
Wall exit, reduced side. Use side shields. 10”
254mm
11”
230mm
21”
534mm
18.5”
470mm
72”
Wall exit, reduced corner. Use side shields and either fan kit or rear 
shield.
7”
180mm
18”
460mm
72”
Alcove, roof exit. Use side shields, and either fan kit or rear shield. 9”
230mm
6”
153mm
20”
510mm
13.5”
343mm
72”
Mobile Home Installation
Roof exit, parallel and corner. Use side shields, either fan kit or rear 
shield and outside air kit.
10”
254mm
6”
153mm
21”
534mm
13.5”
343mm
6”
153mm
17”
433mm
72”
* Check with local codes and pipe manufacturer for pipe clearances. In Canada, 18” clearances from single wall pipe is required.
Alcove Dimensional Requirements: 
Minimum Width 47”, Maximum Depth 48”, Minimum Height above Stove Top, 49”
G = 4” (102mm) in USA
8” (203mm) in Canada
H = 16” (406mm) in USA
18” (456mm) in Canada
I = 0” (0mm) in USA
8” (203mm) in Canada
K = 18” (456mm) for single wall pipe in Canada
 (If K=18”, J=79.375” (2134mm) Minimum)
This stove must be installed in compliance with all local codes and regulations.