Technical information

562600-000, Issue1.0, March 2014
30 of 57
8.1.4 Machine Envelope Controller (MEC) - Height
*The approach limit is configurable at point of calibration, check system operation before
commencing work.
See sections 4.1 and 7.6 for hydraulic override details.
Once a height limit set, the internal alarm will sound and the RED
LED will light if the equipment exceeds the current limit. Always
check that the current limit activates at the set point. The restriction cannot
be deactivated if in the alarm state. Observe the operational limitations
given in section 4.
MEC systems will cut mo-
tion to any section of
equipment that has
reached a limit but allow
other sections to operate
unhindered unless they too
reach the set limit.
The safe directional indicators will be red.
Unsafe motion will be locked and is
indicated by RED arrows/triangles, safe
motion is indicated by GREEN arrows/
triangles
The red LED will flash
The internal alarm will sound
If any of the equipment enters the
approach limit*
The amber LED will be lit
The internal alarm will sound
The message shown here will be
displayed.