Technical information
562600-000, Issue1.0, March 2014  
17 of 57 
7.6  Overload / Hydraulic Limitation Control Override 
7.6.1 Soft Override 
Three seconds after overload has occurred, a soft override but-
ton will become available in the top menu with the supervisor 
keyswitch is in the SET position, see sections 5.5 and 7.6.1. 
If the soft override function is utilised, the machine hydraulics will 
be re-enabled. However, the external alarm will stay active, the 
internal red LED will flash, the blue lamp / Amber lamp will be switched off and an In 
Override message will appear on the display. Once the alarm condition has been cor-
rected the system will automatically revert to normal operation. 
7.6.2 Master Override key Switch 
The system is fitted with a key operated Master override switch. 
Turning the switch to the override position will allow normal opera-
tion of the hydraulic services controlled by PMERail regardless of 
safety status. When the system is in override, the external alarms 
will stay active, the internal red LED will flash, the blue lamp and 
Amber lamp will be switched off and an In Override message will appear on 
the display. The system will automatically return to normal operation after 30 
minutes (default value), See section 4.1 for further details. 
Soft override 










