Technical information
562620-000, Issue1.0, March 2014  
21 of 25 
15  Data Logger 
PMERail has two data-logging functions. The data logging icon appears in the bot-
tom left of the screen. The data can only be viewed by extracting it from the sys-
tem, contact your service agreement holder or Prolec Ltd for further assistance. 
Where a data logging system is found not to be operational then the vehi-
cle shall not be used until the fault is repaired and fully confirmed as op-
erational. This requirement applies irrespective whether starting or part-
way through an operation. 
1.  The Event Logger will make a record of any significant operational event (overload, 
slew limit, etc), any error event (sensor failure etc), any manual intervention 
(override, clock set etc) and any activity within the system set-up (calibration adjust-
ment etc). The event logger will store the past two months worth of data after which 
the oldest data will be deleted on a monthly basis. 
2.  The Periodic Logger records the following data every 1 second: 
      Date       Time 
      Lifting duty    Load on hook 
      Lift point radius  Lift point height 
      Slew angle    Cant 
      Gradient      Operator code 
The event logger will store the past two months worth of operational hours data, (NOT 
elapsed time) after which the oldest data will be deleted on a monthly basis.  










