Technical information

562620-000, Issue1.0, March 2014
21 of 25
15 Data Logger
PMERail has two data-logging functions. The data logging icon appears in the bot-
tom left of the screen. The data can only be viewed by extracting it from the sys-
tem, contact your service agreement holder or Prolec Ltd for further assistance.
Where a data logging system is found not to be operational then the vehi-
cle shall not be used until the fault is repaired and fully confirmed as op-
erational. This requirement applies irrespective whether starting or part-
way through an operation.
1. The Event Logger will make a record of any significant operational event (overload,
slew limit, etc), any error event (sensor failure etc), any manual intervention
(override, clock set etc) and any activity within the system set-up (calibration adjust-
ment etc). The event logger will store the past two months worth of data after which
the oldest data will be deleted on a monthly basis.
2. The Periodic Logger records the following data every 1 second:
Date Time
Lifting duty Load on hook
Lift point radius Lift point height
Slew angle Cant
Gradient Operator code
The event logger will store the past two months worth of operational hours data, (NOT
elapsed time) after which the oldest data will be deleted on a monthly basis.