Technical information
562620-000, Issue1.0, March 2014
10 of 25
6.3 Maintenance Summary
Continued on next page
Job Code Job Description
SFT1 Test overload alarm functionality audibly
SFT2 Test overload blue Lamp functionality visually
SFT3 Test overload amber Lamp functionality visually
SFT4 Test road axle interlock functionality disengages manual control
SFT5 Test rail axle interlock functionality disengages manual control
SFT6 Test travel interlock functionality disengages manual control
SFT7 Test motion cuts to ensure functionality disengages manual control (I.e. Boom UP,
Arm OUT, Slew LEFT - RIGHT)
SFT8 Test speed indicator - tolerance +-10%
LT1 Test height limiter stops the highest section of equipment before the limit, see section
8 of the PMERail Operator Manual - Prolec Part Number 562600-000
LT2 Test slew limiter controls and stops machine before the limit, see section 8 of the
PMERail Operator Manual - Prolec Part Number 562600-000
IGT1 Test In Gauge functionality shows correct state and disengages manual control when
operated
SFC1 Check road axle icon shows correct state on display when operated
SFC2 Check rail axle(s) icon shows correct state on display when operated
SFC3 Check bogie deployment icon shows on display correct state
SFC4 Check offset Boom shows correct state on display when operated
SFC5 Check LUL duty change shows correct state on display when operated
SFC6 Check stabiliser icon shows correct state on display when operated
SFC7 Check counterweight icon shows correct state on display when operated
SFC8 Check supervisor keyswitch icon shows correct state on display when operated
SFC9 Check Master override keyswitch icon shows correct state on display when operated
HRC1
Check lifting point(s) height and radii shows correct values at two positions - toler-
ance +-50mm.
SWLC1
For Road and Road modes (Level rail) reference load chart and compare with SWL
capacity shown with the lifting point at the following 4 points (adjust accordingly if ra-
dius/ height are not appropriate for the machine under test) - tolerance +-2%:
3.0m radius, 2.0m height, 0 degrees
4.5m radius, 2.0m height, 90 degrees
6.0m radius, 2.0m height, 80 degrees
7.5m radius, 2.0m height, 270 degrees