Instruction manual

AccuBeam 3 Digital Line Guide Sensor
78
Bit definitions:
Job Profile
Offset
Calibrate
LED Color
LED Angle
Filter
Threshold
Pattern
Scan Direction
Maximum Left
Minimum Left
Maximum Center
Minimum Center
Maximum Right
Minimum Right
Backlight
Hidden
Read-Only
Start-Up
Bit number
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Hex digit
fifth fourth third second first
Hexadecimal (hex) conversion:
Bit-field Hex digit
0 0 0 0 0
0 0 0 1 1
0 0 1 0 2
0 0 1 1 3
0 1 0 0 4
0 1 0 1 5
0 1 1 0 6
0 1 1 1 7
1 0 0 0 8
1 0 0 1 9
1 0 1 0 A
1 0 1 1 B
1 1 0 0 C
1 1 0 1 D
1 1 1 0 E
1 1 1 1 F
Example: Offset, Backlight, Hidden, Read-Only, and Start-up parameters are hidden
Job Profile
Offset
Calibrate
LED Color
LED Angle
Filter
Threshold
Pattern
Scan Direction
Maximum Left
Minimum Left
Maximum Center
Minimum Center
Maximum Right
Minimum Right
Backlight
Hidden
Read-Only
Start-Up
Bit settings
0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1
Hex digits
2 0 0 0 F