AccuBeam 3 Digital Line Guide Sensor 
77
Hidden 
H  i  d d e n          2 0 0 0 F
This parameter can be configured to hide unused
parameters. If a parameter is Hidden it cannot be selected 
or displayed. 
The value of this parameter is a bit-field and is displayed in 
hexadecimal (hex) format. Each bit corresponds to a
particular parameter – setting a bit to ‘1’ hides the 
parameter, and setting it to ‘0’ makes it visible. Refer to the 
tables on page 78 for bit definitions and hex conversion 
information. 
To activate the Hidden feature the keypad must be
Locked. If the keypad is Unlocked, then all parameters will
be visible, regardless of the Hidden settings. Refer to page 
79 for more information about this feature. 
The default value is 2000F. 
Example: The default value of 2000F (hex) corresponds to 
a bit-field pattern of 0010:0000:0000:0000:1111. This 
pattern hides the Offset, Backlight, Hidden, Read-Only, 
and Start-Up parameters. 
Range: 0 to FFFFF 
Read-Only 
R e a d - O n l y   0
This parameter can be configured to prevent accidental o
r
unauthorized changes to parameters. If a parameter is 
Read-Only it can be displayed but not changed. 
The value of this parameter is a bit-field and is displayed in 
hexadecimal (hex) format. Each bit corresponds to a
particular parameter – setting a bit to ‘1’ makes the 
parameter read-only, and setting it to ‘0’ makes i
t
changeable. Refer to the tables on page 78 for bi
t
definitions and hex conversion information. 
To activate the Read-Only feature the keypad must be 
Locked. If the keypad is Unlocked, then all parameters can 
be changed, regardless of the Read-Only settings. Refe
r
to page 79 for more information about this feature. 
The default value is 0. 
Example: The default value of 0 (hex) corresponds to a bit-
field pattern of 0000:0000:0000:0000:0000. This pattern 
makes all parameters changeable. 
Range: 0 to FFFFF 