Instruction manual
AccuBeam 3 Digital Line Guide Sensor 
75
Maximum Center  (Tracking Parameter) 
M a x   C e n t e r        1 2 7
This parameter specifies the maximum acceptable width o
f
the registration line. This parameter is not used when 
tracking an edge. The default value is 127. 
Range: 0 to 127 pixels 
Note: A setting of 127 disables this Min/Max rule. 
Note: A “pixel” is equivalent to 0.0049” [0.124 mm]. 
Minimum Center  (Tracking Parameter) 
M i n    C e n t e r          0
This parameter specifies the minimum acceptable width o
f
the registration line. This parameter is not used when 
tracking an edge. The default value is 0. 
Range: 0 to 127 pixels 
Note: A setting of 0 disables this Min/Max rule. 
Note: A “pixel” is equivalent to 0.0049” [0.124 mm]. 
Maximum Right  (Tracking Parameter) 
M a x R i g h t         1 2 7
This parameter specifies the maximum acceptable width o
f
the area located to the right of the registration line or edge.
The default value is 127. 
Range: 0 to 127 pixels 
Note: A setting of 127 disables this Min/Max rule. 
Note: A “pixel” is equivalent to 0.0049” [0.124 mm]. 
Minimum Right (Tracking Parameter) 
M i n   R i g h t            0
This parameter specifies the minimum acceptable width o
f
the area located to the right of the registration line or edge. 
The default value is 0. 
Range: 0 to 127 pixels 
Note: A setting of 0 disables this Min/Max rule. 
Note: A “pixel” is equivalent to 0.0049” [0.124 mm]. 