Instruction manual

PointSource™, WideArray™, and Hi-Temp Edge Detectors
58
Setup
The following table lists all sensor models and the corresponding values for controller parameters
12, 13, 24, 25, 36, and 37. Refer to page 17 for more information about setting controller
parameters. Refer to page 61 for more information about the Digital Line Guide.
Sensor
Type
Sensor Model
Number
Sensing Area
Width
inches [mm]
Guide Point
Adjust Range
inches [mm]
Parameter
12, 13,
or 49
Parameter
24 or 25
Parameter
36 or 37
Parameter
55 or 56
Notes
PointSource
Ultrasonic
E/D
1.5x3U 4043-XX 0.2 [5] 0.06 [1.6] 1 2 x 0
3x3U 4050-XX 0.2 [5] 0.06 [1.6] 1 2 x 0
4x6U 4060-XX 0.2 [5] 0.06 [1.6] 1 2 x 0
4x12U 4090-XX 0.2 [5] 0.06 [1.6] 1 2 x 0
Ultrasonic
WideArray
E/D
1.5x3.75U 4612-XX 1.4 [36]
1.2 [30] 1 10 0 0
4x3.75U 4621-XX 1.4 [36]
1.2 [30] 1 10 1 0
1.5x5U 4511-XX 2.6 [66]
2.4 [61] 1 16 0 0
4x5U 4500-XX 2.6 [66]
2.4 [61] 1 16 1 0
1.5x9U 4524-XX 6.6 [168] 6.4 [163] 1 36 0 0
4x9U 4520-XX 6.6 [168] 6.4 [163] 1 36 1 0
4x14U 4530-XX 11.4 [290] 11.2 [284] 1 60 1 0
4x21U 4540-XX 18.6 [472] 18.4 [467] 1 96 1 0
Hi-Temp
Ultrasonic
E/D
UT 4068-XX 0.2 [5] 0.06 [1.6] 1 2 x 2 see note 1
PointSource
Infrared
E/D
1.5x3L 4044-XX 0.2 [5] 0.06 [1.6] 1 2 x 1
3x3L 4051-XX 0.2 [5] 0.06 [1.6] 1 2 x 1
4x6L 4061-XX 0.2 [5] 0.06 [1.6] 1 2 x 1
4x12L 4091-XX 0.2 [5] 0.06 [1.6] 1 2 x 1
Infrared
WideArray
E/D
1.5x3.75L 4611-XX 1.4 [36]
1.2 [30] 1 10 0 1
4x3.75L 4620-XX 1.4 [36]
1.2 [30] 1 10 1 1
1.5x5L 4512-XX 2.6 [66]
2.4 [61] 1 16 0 1
4x5L 4501-XX 2.6 [66]
2.4 [61] 1 16 1 1
1.5x9L 4523-XX 6.6 [168] 6.4 [163] 1 36 0 1
4x9L 4521-XX 6.6 [168] 6.4 [163] 1 36 1 1
1.5x14L 4534-XX 11.4 [290] 11.2 [284] 1 60 0 1
4x14L 4532-XX 11.4 [290] 11.2 [284] 1 60 1 1
Digital
Line
Guide
P/E 5100-XX 0.63 [16] 0.43 [11] 2 x x x
In the table above, x indicates don’t care or not used.
1