Appendix 6 / Discrete Isolated Outputs 
The discrete isolated outputs allow the MICRO 4000 NET system status to be remotely monitored 
by a customer's PLC. There are five status outputs: IN LIMIT, OUT LIMIT, SERVO-CENTER 
LIMIT, AUTO MODE, and NO FAULT. All outputs are opto-isolated. 
Warning:  It is the responsibility of the customer to insure machine safety. Changing the 
mode of operation from any source - front-panel switchpad, fieldbus, or Discrete Isolated 
Inputs - can cause machine motion. 
Electrical Specifications: 
Discrete Isolated Outputs (per output) 
Maximum customer-supplied voltage  31 VDC between any two terminals 
Off-state leakage current  1.0 uA maximum 
On-state resistance  2.5 ohms maximum 
On-state continuous current  0.4 ADC maximum 
On-state peak current  1.2 ADC for 100 msec, repeatable 
every 2 seconds 
Isolation  30 VAC max. between any terminal 
and ground 