Instruction manual
MICRO 4000
®
 NET Controller 
34 
5 8          2 
  The AUXILIARY output is on when Sensor B is nulled. 
5 8          3 
  The AUXILIARY output is on when the system is nulled. 
5 8          4 
  This option is used only for configuring the resolver’s AUXILIARY outpu
t
in resolving-centerline systems. The AUXILIARY output must be
connected to the guide’s AUXILIARY input. 
Centerline Configuration 
5 9          0 
  When Centerline mode is selected, the system will calculate Input A + 
Input B. 
5 9          1 
  When Centerline mode is selected, the system will calculate (Input A +
Input B) / 2. This is the default setting. 
Offset 1 
6 0  1 6 3 8 4 
  This parameter allows Offset 1 to be examined and modified. Offset 1 is 
also accessible through the optional Remote Station or Fieldbus
Interface. To reset Offset 1 to its default value, press the EXIT key. 
The default value is 16384. 
Range: 1 to 32767 
Offset 2 
6 1  1 6 3 8 4 
  This parameter allows Offset 2 to be examined and modified. Offset 2 is
also accessible through the optional Remote Station or Fieldbus
Interface. To reset Offset 2 to its default value, press the EXIT key. 
The default value is 16384. 
Range: 1 to 32767 
Manual Polarity 
6 2          0 
  The actuator extends when the In  mode is selected, and retracts when 
the Out mode is selected. 
6 2          1 
  The actuator extends when the Out mode is selected, and retracts when 
the In mode is selected. This is the default setting. 
Integrator Mode 
6 3          0 
  The integrator function is off. This is the default setting. 
6 3          1 
  This mode is used for applications that require complex control of the
system guide point, but without integration or dampening. 
[continued on next page] 