Instruction manual

MICRO 4000
®
NET Controller
34
5 8 2
The AUXILIARY output is on when Sensor B is nulled.
5 8 3
The AUXILIARY output is on when the system is nulled.
5 8 4
This option is used only for configuring the resolver’s AUXILIARY outpu
t
in resolving-centerline systems. The AUXILIARY output must be
connected to the guide’s AUXILIARY input.
Centerline Configuration
5 9 0
When Centerline mode is selected, the system will calculate Input A +
Input B.
5 9 1
When Centerline mode is selected, the system will calculate (Input A +
Input B) / 2. This is the default setting.
Offset 1
6 0 1 6 3 8 4
This parameter allows Offset 1 to be examined and modified. Offset 1 is
also accessible through the optional Remote Station or Fieldbus
Interface. To reset Offset 1 to its default value, press the EXIT key.
The default value is 16384.
Range: 1 to 32767
Offset 2
6 1 1 6 3 8 4
This parameter allows Offset 2 to be examined and modified. Offset 2 is
also accessible through the optional Remote Station or Fieldbus
Interface. To reset Offset 2 to its default value, press the EXIT key.
The default value is 16384.
Range: 1 to 32767
Manual Polarity
6 2 0
The actuator extends when the In mode is selected, and retracts when
the Out mode is selected.
6 2 1
The actuator extends when the Out mode is selected, and retracts when
the In mode is selected. This is the default setting.
Integrator Mode
6 3 0
The integrator function is off. This is the default setting.
6 3 1
This mode is used for applications that require complex control of the
system guide point, but without integration or dampening.
[continued on next page]