Instruction manual
MICRO 4000
®
 NET Controller 
23
Power-Up Mode 
2 7          0 
  The system will power-up in the same operating mode that was selected 
when last powered-down. All inputs are momentary. This is the default 
setting. 
2 7          1 
  The system will power-up in Manual mode. All inputs are momentary. 
2 7          2 
  The system will power-up in Servo-Center mode. All inputs are 
momentary. 
2 7          3 
  The system will power-up in Automatic mode. All inputs are momentary. 
2 7          4 
  The system will power-up in Manual mode. All inputs are maintained. 
2 7          5 
  The system will power-up in Manual mode and Edge A (Input A) will be 
selected. All inputs are momentary. 
2 7          6 
  The system will power-up in Manual mode and Edge B (Input B) will be 
selected. All inputs are momentary. 
2 7          7 
  The system will power-up in Manual mode and Line (Input C) will be 
selected. All inputs are momentary. 
2 7          8 
  The system will power-up in Manual mode and Edge A and Edge B will 
be selected (Centerline mode). All inputs are momentary. 
Note: This parameter also affects the operation of the Discrete Isolated Inputs (page 46). 
Parameter 28 is reserved for future use. 
System ID 
2 9  x x x x x 
  This parameter displays the system ID number. 
Password 
3 0          0 
  This parameter is used for enabling optional software features. To 
purchase and install optional features, contact AccuWeb for assistance. 
Range: 0 to 255   
Note:  To see which features are enabled, set parameter 29 to 1. The displayed data value 
indicates which feature is enabled: 0 = none, 1 = oscillation, 2 = web width monitor, 4 = integrator. 
Refer to page 43 for a description of parameters 31, 32, 33, and 34. 










