Input A Type 
1 2          0 
  Sensor A is not installed. 
1 2          1 
  Sensor A is an ultrasonic or IR edge detector connected to the Edge
Detector A input. This is the default setting. 
Note: Set parameter 55 to select sensor type. 
1 2          2 
  Sensor A is a digital line guide connected to the Serial I/O interface. 
1 2          3 
  Sensor A is an external analog device connected to Analog Input 1. 
Note: In order to select Input A through the front-panel switchpad, fieldbus or Discrete Isolated 
Inputs, parameter 12 must be set to 1 or higher. 
Input B Type 
1 3          0 
  Sensor B is not installed. This is the default setting. 
1 3          1 
  Sensor B is an ultrasonic or IR edge detector connected to the Edge
Detector B input. 
Note: Set parameter 56 to select sensor type. 
1 3          2 
  Sensor B is a digital line guide connected to the Serial I/O interface. 
1 3          3 
  Sensor B is an external analog device and is connected to Analog Input
2. 
Note: If parameter 2 is set to 1, then Analog Input 2 must be connected 
to the actuator’s position-sensing potentiometer. 
Note 1: In order to select Input B through the front-panel switchpad, fieldbus or Discrete Isolated 
Inputs, parameter 13 must be set to 1 or higher. 
Note 2: In order to select Centerline mode through the front-panel switchpad, fieldbus or Discrete 
Isolated Inputs, parameters 12 and 13 must both be set to 1 or higher. 
Edge Detector A Signal Level 
1 4  a a. b b b 
  This parameter displays edge detector A’s signal levels. Digits aa display 
the beam number and digits bbb display the signal level. Use the DAT
A
buttons to select the desired beam. 
Edge Detector B Signal Level 
1 5  a a. b b b 
  This parameter displays edge detector A’s signal levels. Digits aa display 
the beam number and digits bbb display the signal level. Use the DAT
A
buttons to select the desired beam. 