Maximum Deadband
6 1 0
The maximum deadband is a zone around the sensor guide point where
the motor drive is turned off. The higher the Maximum Deadband value is
set, the farther the web edge or line must move away from the guide
point before the motor drive is turned on. This parameter is typically used
to compensate for edge curl and web flutter. The Maximum Deadband
value must be higher than the Minimum Deadband value. The default
value is 10.
Range: 0 to 100
Auto-Mode Speed Limit
7 8 0
This parameter limits the top speed of the actuator in Automatic mode.
The higher this value is set, the faster the actuator can move. The
default value is 80.
Range: 0 to 120
Manual-Mode Speed
8 8 0
This parameter determines how fast the actuator will move in Manual
and Servo-Center mode. The higher this value is set, the faster the
actuator will move. The default value is 80.
Range: 0 to 120
In End-of-Travel Limit
9 6 7
This parameter works only with actuators that have potentiomete
r
feedback (MT, SF, HL, HF, HT, and UHT). It sets the maximum distance
that the actuator can move In. To increase this distance, set this
parameter to a lower value. The default value is 67.
Important: Refer to page 85 for minimum and maximum values.
Note: Use parameter 26 to examine the current actuator position value.
Range: 0 to 255
Out End-of-Travel Limit
1 0 1 8 9
This parameter works only with actuators that have potentiomete
r
feedback (MT, SF, HL, HF, HT, and UHT). It sets the maximum distance
that the actuator can move Out. To increase this distance, set this
parameter to a higher value. The default value is 189.
Important: Refer to page 85 for minimum and maximum values.
Note: Use parameter 26 to examine the current actuator position value.
Range: 0 to 255
Servo-Center Position
1 1 1 2 8
This parameter works only with actuators that have potentiomete
r
feedback (MT, SF, HL, HF, HT, and UHT). It sets the home position fo
r
the actuator when Servo-Center mode is selected. To move the servo-
center position closer to the In limit, set this parameter to a lower value.
To move the servo-center position closer to the Out limit, set this
parameter to a higher value. The default value is 128.
Important: Refer to page 85 for minimum and maximum values.
Note: Use parameter 26 to examine the current actuator position value.
Range: 0 to 255