Instruction manual
Fieldbus Interface 
123
The module is equipped with four status LEDs mounted at the front of the card and one watchdog 
LED mounted in the middle of the card, used for debugging purposes. The function of the LEDs is 
described in the figure and tables below. Of the four status LEDs, one indicates network status, 
two indicate module status, and one is reserved for future use. 
Status LEDs  Function 
Network status – flashing red, 1 Hz  The In and/or Out length set during configuration 
of the module is not equal to the length set during 
configuration of the network 
Network status – flashing red, 2 Hz  The length/contents of the User Parameter data 
set during configuration of the module is not 
equal to the length/contents set during 
configuration of the network 
Network status – flashing red, 4 Hz  Error in configuration of the Profibus 
communication ASIC 
Network status – off  No diagnostics present 
Module on-line status – green  Module is on-line and data exchange is possible 
Module on-line status – off  Module is not on-line 
Module off-line status – red  Module is off-line and data exchange is not 
possible 
Module off-line status - off  Module is not off-line 
Watchdog LED  Color  Frequency 
No firmware exists  Red  8Hz 
Firmware downloading  Red/Green  1Hz 
ROM check fault  Red  2Hz 
Module not initialized  Green  2Hz 
Module initialized and running OK  Green  1Hz 
RAM check fault  Red  1Hz 
DPRAM check fault  Red  4Hz 
Module on-line status 
Network status 
Reserved 
Module off-line status 