Instruction manual
  MICRO 4000
®
 NET Web Guide Control System 
10 
Operation 
The MICRO 4000 NET may be configured for a wide variety of applications, but most 
configurations share the same basic operating procedure: 
1)  Press the SERVO-CENTER button and wait for the web guide to drive to the center of travel. 
2)  Thread the web through the machine. 
3)  Position the sensors. 
One edge detector: Place the detector near the edge of the web. Move the detector towards 
the web until its null indicator LED turns off. Note:  The scribed lines on the edge detector 
indicate the approximate location of the detector’s guide point. 
Two edge detectors (centerline guiding): Press the EDGE A button. Place detector A near 
the edge of the web. Move detector A towards the web until its null indicator LED turns off. 
Press the EDGE B button. Place detector B near the opposite edge of the web. Move 
detector B towards the web until its null indicator LED turns off. Note: The scribed lines on 
the edge detector indicate the approximate location of the detector’s guide point. 
Digital line guide: Position the sensor so that it is approximately centered over the 
registration line or edge. When it is positioned correctly an indicator dot will appear in the 
display under the line or edge you want to track. Refer to page 61 for more information about 
operating the line guide. 
4)  Press the EDGE A, EDGE B, or LINE button. For Centerline mode (centerline guiding), press 
the EDGE A and EDGE B buttons simultaneously. 
5)  Press the AUTOMATIC button. The system will now guide the web. 
  Scribe mark        Scribe marks 
  Null indicator        Null indicator       
 Move detector until 
null indicator turns off  Web     Web 
PointSource detector  WideArray detector 
Centerline guiding with WideArray detectors 










