Repeat steps c) through h) for each sensor: 
c)  Press the SERVO-CENTER button. 
d)  Position the sensor. 
Edge detector: Place at the edge of the web. The edge detector’s null indicator LED will 
turn off when the edge detector is positioned correctly. The scribed lines on the edge 
detector indicate the approximate location of the detector’s guide point. 
Note:  The default calibration supplied with the system should work for most materials. 
However, if the null indicator LED does not turn off, then the detector may need to be 
calibrated. Refer to page 59 for calibration instructions. 
Digital line guide: Position the sensor so that it is approximately centered over the 
registration line or edge. Calibrate the sensor (refer to page 66 for calibration 
instructions). When the sensor is calibrated and positioned correctly an indicator dot will 
appear in the display under the line or edge you want to track.Press the EDGE A, EDGE 
B, or LINE button to select the sensor under test. 
e)  Press the AUTOMATIC button. 
f)  Slowly move the sensor left or right and observe how the guide reacts. The guide should 
move the web so that it follows (or chases) the movement of the sensor. 
Edge detector: The guide should move the web so that the edge of the web is always 
aligned with the edge detector’s guide point. 
Digital line guide: The guide should move the web so that the line or edge pattern is 
always aligned with the line guide’s sight point. 
Note: If the guide does not follow the movement of the sensor and moves in the opposite 
direction, then the sensor polarity (parameters 3, 4, or 50) is not correct and must be 
changed. Refer to page 17 for more information about setting controller parameters. 
g)  If the guide mechanism oscillates around the guide point or overshoots excessively when 
steering in response to an abrupt change in web position, the servo gain (parameter 5) is 
too high and must be lowered. Refer to page 17 for more information about setting 
controller parameters. 