User`s guide

Using The PHD ULTRA
PUMP OPERATION OVERVIEW
The following diagram provides an overview of basic operation for the PHD ULTRA
:
OVERVIEW OF METHODS
To operate the PHD ULTRA
, you will define all the required parameters for withdrawing or infusing
liquids through a Pump Control Method. The Pump Control Methods will be commonly referred to as
Methods. A Method defines:
Details about the syringe being used for the application
How rapidly you will be dispensing or withdrawing the target fluids
A target volume or target time for the dispensing or withdrawing operation
The pumping pattern you want to employ (e.g. pump at a continuous rate, in a ramped fashion, using
variable rate steps, etc.)
Outbound triggers to external devices
Responses to signals from external devices
The PHD ULTRA
is shipped with a set of pre-installed Methods that are designed to help you to quickly
use the pump in common applications. These pre-installed Methods include:
Quick Start Methods which are simple infuse, withdraw, or combination (infuse and withdraw)
Methods that operate in a single step and at a constant rate of flow.
Preloaded Methods which use more complex Method programming capabilities to describe
commonly encountered applications.
In addition, users of the Infuse/Withdraw Programmable model PHD Ultra can quickly create customize
Methods to support more complex dispensing scenarios including:
NOTE: What Methods are available on your pump depend on the specific model you are
using. An Infuse Only model supports only the Quick Start Infuse Method. The
Infuse/Withdraw model supports all Quick Start Methods and one custom Method. The
Infuse/Withdraw Programmable model supports all Methods described in this manual.
ST EP 1 : Se lec t A Me tho d
Choose an operating Method which defines the syringe being used, the direction
(infuse or withdraw) and rate of flow, as well as any dynamic control of external
devices. If one does not exist, you will create a new Method.
S
TE P 2: Ent er Op era ti ng Par am ete rs
Enter the operating parameters for each step in your method, including specifics
a
bout the syringe/syringes being used, the type of flow operations you want to use,
t
hat rate of flow and any details that define the pumping operation.
ST EP 3 : Pr evi ew You r Met ho d
Check all settings using the Method preview function. Change any required
parameters as necessary.
ST EP 4 : Ru n Yo ur Me tho d
Method Monitor real-time status detailing the progress of the Method.
Harvard Apparatus PHD ULTRA
Syringe Pump Series User's Manual
Publication 5419-002-Rev-A
32
U
sing The PHD ULTRA™