Product data

12 ULTRA Series
Publication 1398-2.0 - August 1999
Two serial connectors to simplify RS-485 multi-dropping and host
communications
Several analog or digital command interfaces:
Indexing (absolute with the Homing feature, incremental, or
registration)
±10 Volt analog interface—position, velocity, or torque control
Presets (from one to eight binary inputs)—torque or velocity control
Quadrature encoder digital interface—electronic gearing position
follower
Step/Direction digital interface—position control
CW/CCW (step up/step down) interface—position control
Operating mode override—alternate movement interface
Host command digital interface
ULTRA 200 Specifications
The following tables contain ULTRA 200 specifications:
General
1
The X indicates the indexing version of the drive.
Specification
1398-DDM-
010, 010X
1
020, 020X
1
030, 030X
1
(1φ input)
075, 075X
1
3φ (1φ)
150, 150X
1
(3φ input)
Peak output current 10A 20A 30A 75A (50A) 150A
Internal continuous output
current
5A 10A 15A 35A (15A) 65A
Internal continuous output
power
1.0 kW 2.0 kW 3.0 kW
7.5 kW
(3.0 kW)
15 kW
Internal continuous shunt
power
50W 50W 50W 50W 180W
Internal peak shunt power 4.5 kW 4.5 kW 4.5 kW 10.0 kW 18.0 kW
Continuous input current 10A 19A 28A 28A 46A
Input voltage 100 to 240V AC RMS nominal (88 to 265 Volts)
Input frequency 47-63 Hz