Connecting Your Ultra1500   3-7
Figure 3.6
Motor Power Cable Shield Connection
Safety Precautions
Observe the following safety precautions when wiring your Ultra1500 drive.
UVW
P2
2092-DA1 or -DA2
Side View
Ground Terminal Screw
Shielded 
Power 
Cable
2092-DA3 
Front View
Ground Terminal Screws 
Shielded 
Power 
Cable
Note: Ground terminal 
arrangement of the 
2092-DA4 and 2092-DA5 
drives. is shown in Figure 
3.5 on page 3-6.
ATTENTION
!
DC bus capacitors may retain hazardous voltages after 
input power has been removed. Before working on the 
drive, measure the DC bus voltage to verify it has reached a 
safe level or wait the full time interval listed on the drive 
warning label. Failure to observe this precaution could 
result in severe bodily injury or loss of life.
Do not attempt to defeat or override the drive fault circuits. 
You must determine the cause of a fault and correct it 
before you attempt to operate the system. If you do not 
correct a drive or system malfunction, it could result in 
personal injury and/or damage to the equipment as a result 
of uncontrolled machine system operation.
Test equipment (such as an oscilloscope or chart recorder) 
must be properly grounded. Failure to include an earth 
ground connection could result in a potentially fatal voltage 
on the oscilloscope chassis.