User manual
Publication 2092-UM001D-EN-P — July 2005
Ultra1500 Connector Data   2-25
Figure 2.25
Timing Requirement s of the Drive Enable Input 
Control Power – L1C and L2C 
L1C and L2C are the single-phase control power inputs for all Ultra1500 
drives. These AC inputs power drive logic and I/O circuitry. 
DC Bus Negative – N 
N is the negative side of the DC power bus on all 2092 drives. 
Note: The positive side (P) of the DC power bus is provided on the DC Bus 
and Shunt power connector. 
If the 2092 drive is to be powered from a DC source, the DC power supply is 
connected to P2 on the DC Bus and Shunt power connector, and N on the 
Main Input power connector. The L1, L2, L3, and P1 terminals should be 
disconnected. 
IMPORTANT
The drive requires 500 ms after the main AC input has 
been applied before it can be enabled, as shown in Figure 
2.25. 
ATTENTION
!
The N terminal (labelled DC- on the removable connector) IS NOT an 
Input Power connection.
t
DELAY
 = 500mS, minimum 
Main AC 
Input 
DC Bus 
Voltage 
Drive Enable
(software or 
hardware) 