User manual
Publication 2092-UM001D-EN-P — July 2005
1-16 Installing Your Ultra1500
Mounting Your Ultra1500 
Drive
The procedures in this section assume you have prepared your panel and 
understand how to bond your system. For installation instructions regarding 
other equipment and accessories, refer to the instructions that came with each 
of the accessories for their specific requirements.
To mount your Ultra1500 drive:
1. Layout the position for the Ultra1500 and accessories in the enclosure 
(refer to Establishing Noise Zones for panel layout recommendations). 
Dimensions for the Ultra1500 are shown in Figure 1.6. 
2. Attach the Ultra1500 to the cabinet, first using the lower mounting slots of 
the drive and then the upper. The recommended mounting hardware is 
M4 x 10 metric bolts for 2092-DA1 through 2092-DA3 drives, or M5 x 10 
metric bolts for 2092-DA4 and 2092-DA5 drives. Observe bonding 
techniques as described in HF Bonding Your System.
3. Tighten all mounting fasteners.
ATTENTION
!
This drive contains ESD (Electrostatic Discharge) sensitive 
parts and assemblies. You are required to follow static 
control precautions when you install, test, service, or repair 
this assembly. If you do not follow ESD control 
procedures, components can be damaged. If you are not 
familiar with static control procedures, refer to 
Allen-Bradley publication 8000-4.5.2, Guarding Against 
Electrostatic Damage or any other applicable ESD Protection 
Handbook.
IMPORTANT
To improve the bond between the Ultra1500 and 
subpanel, construct your subpanel out of zinc plated 
(paint-free) steel.