User manual

Publication 2092-UM001D-EN-P — July 2005
D-32 Ultra1500 Operator Interface
Pr-6.15 Alternate Gain: VReg Low Pass Bandwidth
Description:
This command allows you to set an Alternate Velocity
Regulator Low Pass Bandwidth for use in tuning.
Range: 0 to 10000
Default: 1000
Units: Hz
Applicable Operating Mode: Follower, Analog Velocity, Preset Velocity
Ultraware Link: Alternate Gain Values: VReg Low Pass Bandwidth