User manual
Publication 2092-UM001D-EN-P — July 2005
Ultra1500 Operator Interface D-29
Group 6 Parameters 
Group 6 parameters provide supplementary gain settings and fault reports. 
Pr-6.00 Analog Velocity Command Offset
Pr-6.01 Analog Current Command Offset
Pr-6.02 Reserved 
Pr-6.03 Reserved 
Pr-6.04 Velocity Regulator D Gain
Units: 
See Monitor Variable Numbers (except 0x0F) beginning on 
page D-6.
Applicable Operating Mode:  All
Ultraware Link:  Analog Output 2: Scale
Description:  The offset to the Analog Velocity Command input. 
Range:  -10000 to 10000
Default:  0
Units:  0.1 mV
Applicable Operating Mode:  Analog Velocity
Ultraware Link:  Analog Velocity Command Offset
Description:  The offset to the Analog Current Command input. 
Range:  -10000 to 10000 
Default:  0 
Units:  0.1 mV 
Applicable Operating Mode:  Analog Current
Ultraware Link:  Analog Current Command Offset 
This parameter is Reserved.
This parameter is Reserved.
Description: 
Gain value for the velocity loop that is derived from the 
velocity error. 
Range:  0 to 1000










