User manual
Publication 2092-UM001D-EN-P — July 2005
Ultra1500 Operator Interface D-25
Pr-4.06 Initial Current Bias
Group 5 Parameters 
Group 5 Parameters provide supplementary drive system and I/O settings
Pr-5.00 Position Functions: In Position Size
Pr-5.01 Position Functions: Near Position Size
Pr-5.02 Speed Functions: Speed Window
Ultraware Link:  Initial Current Bias
Description:  Prevents the downturn of vertical load during initial operation
Range:  -100 to100
Default:  0
Units:  % of motor rated continuous current
Applicable Operating Mode:  All
Description: 
If the position error is within the limit set in In Position Size 
and a digital output is defined as In Position, then the digital 
output is turned ON. 
Range:  0 to 2500
Default:  10
Units:  Counts
Applicable Operating Mode:  Follower
Ultraware Link:  Position Functions: In Position Size
Description: 
If the position error is within the limit set in Near Position Size 
and a digital output is defined as Near Position, then the 
digital output is turned ON. 
Range:  0 to 2500
Default:  20
Units:  Counts
Applicable Operating Mode:  Follower
Ultraware Link:  Position Functions: Near Position Size
Description: 
If the speed error is within the limit set in Speed Window and 
a digital output is defined as Within Speed Window, then the 
digital output is turned ON. 
Range:  0 to 1000
Default:  10
Units:  rpm for rotary motors