User manual
Publication 2092-UM001D-EN-P — July 2005
D-24 Ultra1500 Operator Interface
Pr-4.01 Current Limits: Positive Internal
Pr-4.02 Current Limits: Negative Internal
Pr-4.03 Current Limits: Positive External
Pr-4.04 Current Limits: Negative External
Pr-4.05 Stopping Functions: Maximum Stopping Current
Units:  % of rated continuous current/V*10
Applicable Operating Mode:  Analog Current, Dual Current
Ultraware Link:  Current Scale
Range:  0 to 500
Default:  500
Units:  % of motor rated continuous current
Applicable Operating Mode:  All
Ultraware Link:  Current Limits: Positive Internal
Range:  0 to 500
Default:  500
Units:  % of motor rated continuous current
Applicable Operating Mode:  All
Ultraware Link:  Current Limits: Negative Internal
Range:  0 to 500
Default:  100
Units:  % of motor rated continuous current
Applicable Operating Mode:  All
Ultraware Link:  Current Limits: Positive External
Range:  0 to 500
Default:  100
Units:  % of motor rated continuous current
Applicable Operating Mode:  All
Ultraware Link:  Current Limits: Negative External
Range:  0 to 500
Default:  500
Units:  % of motor rated continuous current
Applicable Operating Mode:  All
Ultraware Link:  Stopping Functions: Maximum Stopping Current 










