User manual

Publication 2092-UM001D-EN-P — July 2005
D-24 Ultra1500 Operator Interface
Pr-4.01 Current Limits: Positive Internal
Pr-4.02 Current Limits: Negative Internal
Pr-4.03 Current Limits: Positive External
Pr-4.04 Current Limits: Negative External
Pr-4.05 Stopping Functions: Maximum Stopping Current
Units: % of rated continuous current/V*10
Applicable Operating Mode: Analog Current, Dual Current
Ultraware Link: Current Scale
Range: 0 to 500
Default: 500
Units: % of motor rated continuous current
Applicable Operating Mode: All
Ultraware Link: Current Limits: Positive Internal
Range: 0 to 500
Default: 500
Units: % of motor rated continuous current
Applicable Operating Mode: All
Ultraware Link: Current Limits: Negative Internal
Range: 0 to 500
Default: 100
Units: % of motor rated continuous current
Applicable Operating Mode: All
Ultraware Link: Current Limits: Positive External
Range: 0 to 500
Default: 100
Units: % of motor rated continuous current
Applicable Operating Mode: All
Ultraware Link: Current Limits: Negative External
Range: 0 to 500
Default: 500
Units: % of motor rated continuous current
Applicable Operating Mode: All
Ultraware Link: Stopping Functions: Maximum Stopping Current