Pr-3.01 Gear Ratio Follower Lines 
Pr-3.02 Gear Ratio, Master Counts
Pr-3.03 Encoder Output Ratio, Output Counts
Pr-3.04 Encoder Output Ratio, Motor Counts
Group 4 Parameters 
Group 4 Parameters provide torque control settings. 
Pr-4.00 Analog Current Scale 
Gear Ratio Follower Lines
Range:  1 to 65535 
Default:  1
Units:  Counts/4 = Lines 
Applicable Operating Mode:  Follower
Ultraware Link:  Gear Ratio Follower Lines 
Range:  1 to 65535 
Default:  4
Units:  Counts 
Applicable Operating Mode:  Follower
Ultraware Link:  Gear Ratio, Master Counts
Range:  1 to 65535 
Default:  2048
Units:  Counts
Applicable Operating Mode:  All
Ultraware Link:  Output Ratio, Output Counts 
Range:  1 to 65535 
Default:  2048
Units:  Counts
Applicable Operating Mode:  All
Ultraware Link:  Output Ratio, Motor Counts
Range:  0 to 1000
Default:  333