User manual
Publication 2092-UM001D-EN-P — July 2005
Ultra1500 Operator Interface D-13
Pr-0.07 Input Signal Assignment - Group 3
Pr-0.08 Input Signal Assignment - Group 4
8 Input Signal ON
Data Size: 4 digits 
Digits: Digit Description  Default
0 Fault Reset 0x0
1 Current Limit – Negative 0x0
2 Current Limit – Positive 0x0
3 Operation Mode Override 0x0
Applicable Operating Mode All
Range for all digits:  0 to 8 
Value Description 
0 Input Signal OFF
1 to 7 
Input signal assigned to 
hardware inputs 1 through 7
8 Input Signal ON
Data Size:  4 digits 
Digits: Digit Description Default
0 Preset Direction 0x0 
1 Preset Select 1  0x0 
2 Preset Select 2 0x0 
3 Preset Select 3 0x0 
Applicable Operating Mode  All
Range for all digits:  0 to 8 
Value Description 
0 Input Signal OFF
1 to 7 
Input signal assigned to 
hardware inputs 1 through 7
8 Input Signal ON
Data Size:  4 digits 
Digits: Digit Description Default
0 Zero Clamp 0x0 
1 Pause Follower 0x0 
2  Alternate Gain Select 0x0 
3 
Absolute Encoder Reset of 
multi-turn data
0x0 
Applicable Operating Mode  All