User manual
Publication 2092-UM001D-EN-P — July 2005
B-6 Interconnect and Cable Diagrams
Generic Controller 
Connections
Figure B.5 shows the recommended connections for a typical system using a 
generic motion controller.
Figure B.5
Ultra1500 to Generic Controller System Interface Diagram
3
RD
 PARTY 
CONTROLLER
CMD+ 
CMD- 
ENABLE+ 
NOTES: 
1.  IN THIS EXAMPLE, THE CONTROLLER PROVIDES A VELOCITY COMMAND TO THE DRIVE AND THE DRIVE CLOSES THE VELOCITY LOOP. IF 
THE APPLICATION REQUIRES THE CONTROLLER TO CLOSE THE VELOCITY LOOP, THE CURRENT COMMAND OF THE CONTROLLER SHOULD 
BE CONNECTED TO THE ANALOG CURRENT COMMAND INPUT OF THE DRIVE INSTEAD, FOUND ON PINS 21 AND 22. 
2.  INPUT1 MUST BE CONFIGURED TO HAVE ENABLE FUNCTIONALITY USING ULTRAWARE. 
3.  THIS DRAWING ASSUMES THAT THE ENABLE OUTPUTS OF THE CONTROLLER ARE RELAY CONTACTS. CHECK THE INSTALLATION 
MANUAL FOR OTHER POSSIBLE CONFIGURATIONS. 
4.  THIS DRAWING ASSUMES THAT THE DRIVE FAULT INPUT OF THE CONTROLLER IS ACTIVE HIGH, CURRENT SINKING. CHECK THE 
INSTALLATION MANUAL FOR OTHER POSSIBLE CONFIGURATIONS. 
5.  OUTPUT2 MUST BE CONFIGURED TO HAVE DRIVE READY FUNCTIONALITY USING ULTRAWARE. 