User manual

Publication 2092-UM001D-EN-P — July 2005
Installing Your Ultra1500 1-3
Low Voltage Directive
These units are tested to meet Council Directive 73/23/EEC Low Voltage
Directive. The standard EN 50178 Electronic Equipment for use in Power
Installations applies in whole or in part.
Refer to Appendix B for interconnect information.
Meeting Emission Requirements
To meet emission requirements the following components are required:
Install an AC line filter (2090-UXLF-xxx or -HVxxx) between the AC
power source and the drive input, and as close to the drive as possible
(refer to Appendix C for available AC line filters).
Connect both Main and Control input power to the load side of the AC
line filter for the drive.
Use 2090 series motor power and feedback cables and terminate the
power cable shields to the drive chassis and motor/machine frame.
Install the Ultra1500 system inside an enclosure (grounded to the
enclosure), and run input power wiring in conduit outside of the
enclosure.
Separate signal and power cables as shown in Planning Your Panel Layout of
this chapter.
Install ferrites on the AC input power cable, and motor (output) power
cable, and motor feedback cable nearest the drive. Steward 28A2024-QAO
has demonstrated compliance on the motor feedback cable, and Steward
28R2024-ORO has been qualified with the power cables.