User manual

Publication 2092-UM001D-EN-P — July 2005
A-2 Specifications and Dimensions
Ultra1500 Power
Specifications
The following sections provide power specifications for the Ultra1500.
Ultra1500 Power Specifications
The tables below lists general power specifications and requirements for the
Ultra1500 drives (2092-DAx).
Main Input Power
Control Input Power
Input Power Connector
Drives 2092-DA1 2092-DA2 2092-DA3 2092-DA4 2092-DA5
Input Voltage
1
200–240 Vrms, 1φ 200–240 Vrms, 3φ
Input Current
2
3.3 Arms 5.5 Arms 8.0 Arms 11.0 Arms 15.0 Arms
Input Frequency 47–63 Hz
Inrush Current
2
200 Apeak, maximum
Power Cycling 0.5 power cycles/minute maximum
Delay before Drive Enable 500ms, minimum (after main power is applied)
1 Specifications are for nominal voltage. The absolute limits are +/-10% (180–265 Vrms).
2 Power initialization requires a short period of inrush current. Dual element time delay (slow blow) fuses are recommended in Fuse and Contactor
Specifications on page A-4.
Input Voltage
1
200–240 Vrms, 1φ
Input Current
2
2.0 Arms
Input Frequency 47–63 Hz
Inrush Current
2
75 Apeak, maximum
1 Specifications are for nominal voltage. The absolute limits are +/-10% (180–265 Vrms).
2 Power initialization requires a short period of inrush current. Dual element time delay (slow blow) fuses are
recommended in Fuse and Contactor Specifications on page A-4.
Description Pluggable cage-clamp, 7.5mm spacing
Manufacturer Wago 231-206/026-000
Acceptable Wire Gauge
2.5–0.5 mm
2
(14–20 AWG)
Operating Tool Wago 231-131
Pinout Refer to Input Power Connectors on page 2-24