The velocity command limit is set to the minimum of the following:
• Zero if the velocity command is in the direction of an active overtravel
limit,
• Manual Velocity Limit (if activated),
• Analog Velocity Limit (if activated), and
• Motor rated speed.
The current command limit is set to the minimum of the following:
• Positive / Negative Internal Current Limit,
• Positive / Negative External Current Limit,
• Stopping Current (if activated), and
• Drive Peak / Motor Peak Current Rating.
Analog Velocity Mode
Figure 5.22 shows the block diagram of the analog velocity mode for the
Ultra1500:
Figure 5.22
Analog Velocity Mode Block Diagram
Block/Switch definitions shown in Figure 5.22 refer to the Ultraware parameter names where applicable.
+
+